Interzoll Modul | Subrack for connectors (.12)
Subrack 3 U for connectors (.12)
| Model | Order no. | A | B | C | b1 | IP | NEMA | HE | TE | Article Colour | Cards depth |
| BGT/M 18340.12 | 85183405 | 132.5 | 269.24 | 178 | 213.64 | 20 | 1 | 3 | 42 | -- | 160 |
| BGT/M 24340.12 | 85243405 | 132.5 | 269.24 | 238 | 213.64 | 20 | 1 | 3 | 42 | -- | 160, 220 |
| BGT/M 30340.12 | 85303405 | 132.5 | 269.24 | 298 | 213.64 | 20 | 1 | 3 | 42 | -- | 160, 220, 280 |
| BGT/M 36340.12 | 85363405 | 132.5 | 269.24 | 358 | 213.64 | 20 | 1 | 3 | 42 | -- | 160, 220, 280, 340 |
| BGT/M 18360.12 | 85183605 | 132.5 | 375.92 | 178 | 320.32 | 20 | 1 | 3 | 63 | -- | 160 |
| BGT/M 24360.12 | 85243605 | 132.5 | 375.92 | 238 | 320.32 | 20 | 1 | 3 | 63 | -- | 160, 220 |
| BGT/M 30360.12 | 85303605 | 132.5 | 375.92 | 298 | 320.32 | 20 | 1 | 3 | 63 | -- | 160, 220, 280 |
| BGT/M 36360.12 | 85363605 | 132.5 | 375.92 | 358 | 320.32 | 20 | 1 | 3 | 63 | -- | 160, 220, 280, 340 |
| BGT/M 18380.12 | 85183805 | 132.5 | 482.6 | 178 | 427 | 20 | 1 | 3 | 84 | -- | 160 |
| BGT/M 24380.12 | 85243805 | 132.5 | 482.6 | 238 | 427 | 20 | 1 | 3 | 84 | -- | 160, 220 |
| BGT/M 30380.12 | 85303805 | 132.5 | 482.6 | 298 | 427 | 20 | 1 | 3 | 84 | -- | 160, 220, 280 |
| BGT/M 36380.12 | 85363805 | 132.5 | 482.6 | 358 | 427 | 20 | 1 | 3 | 84 | -- | 160, 220, 280, 340 |
Notes:
If the ejector handles are used acc. to DIN IEC 60297-3-102 / IEEE 1101.10, the subrack must be fitted with the appropriate PF/M 000.. BN-HG front profile. The required subracks can be supplied on request.
The dimensions are approximate values. The exact values can be found in the respective product drawing.
If the ejector handles are used acc. to DIN IEC 60297-3-102 / IEEE 1101.10, the subrack must be fitted with the appropriate PF/M 000.. BN-HG front profile. The required subracks can be supplied on request.
The dimensions are approximate values. The exact values can be found in the respective product drawing.
Scope of delivery:
1) 2 side panels (BSW/M ..300)
2) 2 flanges (FL/M 00300)
3) 2 front profiles (PF/M 000..)
4) 2 bus profiles (PB/M 000..)
5) Mounting material (BFS/M 0100)
6) 2 tapped strips (GS/M)
7) 2 M2.5 (GSE/M) slotted set screws
1) 2 side panels (BSW/M ..300)
2) 2 flanges (FL/M 00300)
3) 2 front profiles (PF/M 000..)
4) 2 bus profiles (PB/M 000..)
5) Mounting material (BFS/M 0100)
6) 2 tapped strips (GS/M)
7) 2 M2.5 (GSE/M) slotted set screws
Subrack 6 U for connectors (.12)
| Model | Order no. | A | B | C | b1 | IP | NEMA | HE | TE | Article Colour | Cards depth |
| BGT/M 18640.12 | 85186405 | 265.9 | 269.24 | 178 | 213.64 | 20 | 1 | 6 | 42 | -- | 160 |
| BGT/M 24640.12 | 85246405 | 265.9 | 269.24 | 238 | 213.64 | 20 | 1 | 6 | 42 | -- | 160, 220 |
| BGT/M 30640.12 | 85306405 | 265.9 | 269.24 | 298 | 213.64 | 20 | 1 | 6 | 42 | -- | 160, 220, 280 |
| BGT/M 36640.12 | 85366405 | 265.9 | 269.24 | 358 | 213.64 | 20 | 1 | 6 | 42 | -- | 160, 220, 280, 340 |
| BGT/M 18660.12 | 85186605 | 265.9 | 375.92 | 178 | 320.32 | 20 | 1 | 6 | 63 | -- | 160 |
| BGT/M 24660.12 | 85246605 | 265.9 | 375.92 | 238 | 320.32 | 20 | 1 | 6 | 63 | -- | 160, 220 |
| BGT/M 30660.12 | 85306605 | 265.9 | 375.92 | 298 | 320.32 | 20 | 1 | 6 | 63 | -- | 160, 220, 280 |
| BGT/M 36660.12 | 85366605 | 265.9 | 375.92 | 358 | 320.32 | 20 | 1 | 6 | 63 | -- | 160, 220, 280, 340 |
| BGT/M 18680.12 | 85186805 | 265.9 | 482.6 | 178 | 427 | 20 | 1 | 6 | 84 | -- | 160 |
| BGT/M 24680.12 | 85246805 | 265.9 | 482.6 | 238 | 427 | 20 | 1 | 6 | 84 | -- | 160, 220 |
| BGT/M 30680.12 | 85306805 | 265.9 | 482.6 | 298 | 427 | 20 | 1 | 6 | 84 | -- | 160, 220, 280 |
| BGT/M 36680.12 | 85366805 | 265.9 | 482.6 | 358 | 427 | 20 | 1 | 6 | 84 | -- | 160, 220, 280, 340 |
Notes:
If the ejector handles are used acc. to DIN IEC 60297-3-102 / IEEE 1101.10, the subrack must be fitted with the appropriate PF/M 000.. BN-HG front profile. The required subracks can be supplied on request.
The dimensions are approximate values. The exact values can be found in the respective product drawing.
If the ejector handles are used acc. to DIN IEC 60297-3-102 / IEEE 1101.10, the subrack must be fitted with the appropriate PF/M 000.. BN-HG front profile. The required subracks can be supplied on request.
The dimensions are approximate values. The exact values can be found in the respective product drawing.
Scope of delivery:
1) 2 side panels (BSW/M ..600)
2) 2 flanges (FL/M 00600)
3) 2 front profiles (PF/M 000..)
4) 2 rear profiles (PR/M 000.. .12)
5) 1 double connector profile (PSD/M 006.. .12)
6) Mounting material (BFS/M 0100)
7) 2 tapped strips (GS/M)
8) 2 M2.5 (GSE/M) slotted set screws
1) 2 side panels (BSW/M ..600)
2) 2 flanges (FL/M 00600)
3) 2 front profiles (PF/M 000..)
4) 2 rear profiles (PR/M 000.. .12)
5) 1 double connector profile (PSD/M 006.. .12)
6) Mounting material (BFS/M 0100)
7) 2 tapped strips (GS/M)
8) 2 M2.5 (GSE/M) slotted set screws