Array ( [MP] => 137-92 )

Protection Classification IP 30 to DIN EN 60529 (VDE 0470)

The protection classification offered by an enclosure is shown by the letter IP (Ingress Protection) and two digits. The first digit indicates two factors:

    1. Protection for persons
    2. Protection for equipment

The second digit indicates the protection against water.

First digit: 3

Protection for persons: Protection against a tool touching dangerous parts.
Definition: A body 2,5 mm in diameter must not be able to enter. IP 3X

Test conditions: The accessing probe is pushed against every opening of the enclosure with a standardised force or is inserted through the opening.
Conditions for acceptance: The protection is satisfactory if a sufficient distance between the accessing probe and dangerous parts is kept.
Protection for equipment: Protection against a solid foreign body 2,5 mm or more in diameter.
Definition: A round body 2,5 mm in diameter must not enter at all.
Test conditions: The object probe is pushed against every opening of the enclosure with a standardised force.
Conditions for acceptance: The protection is satisfactory if the entire diameter of the probe does not fit into an opening.

 

Second digit: 0

Protection against water : No protection
Definition: - IP X0

Test conditions: -
Conditions for acceptance: -

Important note: